EXTR instruction is provided for FX2N/FX2NC PLCs.
For FX
3S/FX3G/FX3GC/FX3U/FX3UC PLCs equipped with the built-in inverter communication function, dedicated
instructions shown below are provided. (EXTR instruction is not provided.)
Instruction correspondence table
*1. This function is supported only in FX3U/FX3UC PLCs.
→ For details, refer to the Data Communication Edition manual.
FX2N/FX2NC FX3S/FX3G/FX3GC/FX3U/FX3UC Description
EXTR K10 → FNC270 IVCK Inverter status check
EXTR K11 → FNC271 IVDR Inverter drive
EXTR K12 → FNC272 IVRD Inverter parameter read
EXTR K13 → FNC273 IVWR Inverter parameter write
– – FNC274
IVBWR
*1
Inverter parameter block write
– – FNC275 IVMC Inverter multi command