37 Operation of Special Devices (M8000 -, D8000 -)
37.1 Special Device List (M8000 -, D8000 -)
31
FNC277-FNC279
Data
Transfer 3
32
FNC280-FNC289
High-Speed
Processing 2
33
FNC290-FNC299
Extension File
Register Control
34
FNC300-FNC305
FX
3U
-CF-ADP
35
SFC•STL
Programming
36
Interrupt
Function
37
Special Device
38
Error Code
A
Version Up
Information
B
Execution Times
High-Speed Counter Comparison, High-Speed Table, and Positioning [Positioning is supported in FX3S/FX3G/FX3GC/FX1S/FX1N/FX1NC]
M 8130
HSZ (FNC 55) instruction:
Table comparison mode
D8130
–––
[M]8131
HSZ (FNC 55) instruction:
Table comparison mode completion flag
–––
M 8132
HSZ (FNC 55) and PLSY (FNC 57) instructions:
Speed pattern mode
D8131 to
D8134
–––
[M]8133
HSZ (FNC 55) and PLSY (FNC 57) instructions:
Speed pattern mode completion flag
–––
[M]8134
Not used
–––––
[M]8135 –––––
[M]8136 –––––
[M]8137 –––––
[M]8138
HSCT (FNC280) instruction:
Instruction execution complete flag
D8138–––––
[M]8139
HSCS (FNC 53), HSCR (FNC 54), HSZ (FNC
55), HSCT (FNC280) instructions:
High-speed counter comparison instruction
executing
D8139–––––
M 8140
ZRN (FNC156) instruction:
CLR signal output function enable
––––
[M]8141
Not used
–––––
[M]8142 –––––
[M]8143 –––––
[M]8144 –––––
M 8145 [Y000] Pulse output stop command ––––
M 8146 [Y001] Pulse output stop command ––––
[M]8147 [Y000] Pulse output monitor (BUSY/READY) ––––
[M]8148 [Y001] Pulse output monitor (BUSY/READY) ––––
[M]8149 Not used –––––
Inverter Communication Function (Refer to Data Communication Edition for details.)
[M]8150 Not used –––––
[M]8151 Inverter communication in execution [ch1]
*3
D8151–––––
[M]8152
*1
Inverter communication error [ch1]
*3
D8152–––––
[M]8153
*1
Inverter communication error latch [ch1]
*3
D8153–––––
[M]8154
*1
IVBWR (FNC274) instruction error [ch1] D8154–––––
[M]8154 Defined per use of EXTR (FNC180)
–––
*2
*2
[M]8155 EXTR (FNC180) is using communicating port D8155
*2
*2
[M]8156 Inverter communication in execution [ch2]
*3
D8156–––––
[M]8156
Communication error or parameter error in
EXTR (FNC180) instruction
D8156
*2
*2
[M]8157
*1
Inverter communication error [ch2]
*3
D8157–––––
Communication error in EXTR (FNC180)
instruction is latched.
D8157
*2
*2
[M]8158
*1
Inverter communication error latch [ch2]
*3
D8158–––––
[M]8159
*1
IVBWR (FNC274) instruction error [ch2] D8159–––––
*1. Cleared when PLC switches from STOP to RUN.
*2. Available in Ver. 3.00 or later.
*3. Available in Ver. 1.10 or later.
Number and
name
Operation and function
Applicable model
FX
3S
FX
3G
FX
3GC
FX
3U
FX
3UC
Correspond-
ing special
device
FX
1S
FX
1N
FX
1NC
FX
2N
FX
2NC