Mitsubishi Electronics A171SHCPUN Home Security System User Manual


 
1. SPECIFICATIONS OF MOTION SYSTEM COMPONENTS
1
10
1.4 General Specifications
Table 1.1 Generation Specifications
Item Specification
Operating ambient
temperature
0 to 55
°
C
Storage ambient
temperature
-20 to 75
°
C
Operating ambient
humidity
10% to 90%RH, no condensation
Storage ambient
humidity
10% to 90%RH, no condensation
Frequency Acceleration Amplitude
Number of Sweeps
10 to 55Hz
0.075mm
(0.003 in)
Vibration resistance
Conforms to JIS C
0911*
2
55 to 150Hz 9.8m/s
2
10
(1 octave/minute)*
1
Shock resistance Conforms to JIS C 0912 (98m/s
2
(10g), 3 directions, 3 times)*
2
Noise resistance
(1) Noise voltage: 1500Vpp, noise amplitude: 1
µ
s, noise frequency: 25 to 60 Hz, with a noise simulator
(2) Noise voltage : IEC801-4, 2 kV
Withstand voltage 2830VAC rms/3 cycles across all inputs/LG and all outputs/FG (altitude 2000m (6557.38ft.))
Insulation resistance 5M
or more by 500VDC insulation resistance tester across all inputs/LG and all outputs/FG
Ground Class 3 grounding. Connect to enclosure when grounding is impossible.
Operating environment No corrosive gas, low dust
Cooling method Natural cooling.
REMARKS
*1 An “octave” refers to an increase or decrease in frequency by a factor of
two. For example, the following are all octaves: 10 Hz to 20 Hz, 20 Hz to
40 Hz, 40 Hz to 20 Hz, and 20 Hz to 10 Hz.
Refer to “CHAPTER 2 DESIGN” for the installation environment and
mounting instructions.
*2 JIS: Japan Industrial Standards
WARNING
Class 3 grounding should be used. The motion controller should not share a common ground with
any other equipment. The ground terminal is located on the motion controller module terminal
block. (See Section 1.5.2.)
CAUTION
The motion controller must be stored and operated under the conditions listed in the table of
specifications above.
Disconnect the power cables from the motion controller if it is to remain unused for a long period
of time.
Insert a controller or servo amplifier into the static-proof vinyl bag for storage.
Consult the system service or service station before storing equipment for a long period of time.