DMP Electronics XR2500F Smoke Alarm User Manual


 
Digital Monitoring Products XR2500F Installation Guide
32
CoMPlIanCe
Holdup Alarm Units
ANSI/UL 636
29.1 ANSI/UL 1610 Required
Theprogrammingandinstallationspecicationscontainedinthissectionmustbecompletedinadditionto
ANSI/UL1610SpecicationswheninstallingaModel1142withaModelXR500Seriespanel.
29.2 1100X Wireless Receiver
TheModel1100XWirelessReceiverinconjunctionwiththeModel1142HoldupAlarmTransmittermustbe
installed in the system.
29.3 Wireless Supervision Time
TheZoneInformationSupervisionTimemustbeamaximumof240minutes.
29.4 LED Display
TheLEDOperationoptiondisplaymustbesettoNOwhenusingaModel1142HoldupAlarmTransmitter.
29.5 Jamming Detection
TheDetectWirelessJammingoptionmustbesettoYES.
29.6 Local Alarm
TheBellActionforaPN(Panic)typezonemustbeprogrammedasN(None).
29.7 Message to Transmit
TheArmedOpenandArmedShortmessagesforaPN(Panic)typezonemustbeprogrammedtoA(Alarm).
29.8 Wireless Audible Annunciation Option
TheWirelessAudibleoptionmustbeselectedasANYforcommercialapplications.
Digital Burglar Alarm Communicator System Units
ANSI/ UL 1635
30.1 System Trouble Display
TheStatusListDisplaymustincludeatleastonekeypadthatdisplayssystemmonitortroubles.
30.2 Digital Dialer Telephone Number
BothprogrammedtelephonenumbersmustbeginwithaP.
30.3 Test Time
TheTestTimeoptionmustbeprogrammedsothattheXR2500Fsendsareportonceevery24hours.
30.4 Closing Wait
TheClosingWaitoptionmustbeprogrammedYES.
Police Station Connected and Local Burglar Alarm Units
ANSI/UL 365
31.1 System Trouble Display
TheStatusListDisplaymustincludeatleastonekeypadthatdisplayssystemmonitortroubles.
31.2 Entry Delay
Themaximumentrydelayusedmustnotbemorethan60secondswhenusingModel350Aor350HAttack
housing.
31.3 Exit Delay
Themaximumexitdelayusedmustnotbemorethan60seconds.