Secondary Power Supply
4.1 Description
TheXR2500Fsystemincludespre-wiredcablesforconnecting12VDCbatterytotheXR2500Fpanel.Observe
polaritywhenconnectingallbatteries.
Use sealed lead-acid batteries only.UsetheDMPModel367,368,369,365,366,12VDCsealedlead-acid
rechargeablebatteries.BatteriessuppliedbyDMPhavebeentestedtoensureproperchargingwithDMP
products.
GelcellbatteriescannotbeusedwiththeXR2500Fpanel.
4.2 Battery Connection to XR2500F Command Processor panel
For12VDCbatteryoperationtotheXR2500F,connecttheblackbatteryleadtothebatterynegative
terminal. The black battery wire connects to XR2500F panel terminal 4.
Connect the red battery lead to the battery positive terminal. The red battery wire connects to XR2500F
panelterminal3.SeeFigure11andFigure2.
AddasecondbatteryinparallelusingtheDMPModel318DualBatteryHarness.Whenwiringtwobatteries
withtheModel318DualBatteryHarness,plugtheDualBatteryHarnessredmaleendintothepanelred
femalebatterylead.PlugtheDualBatteryHarnessblackmaleendintothepanelblackfemalebattery
lead.AttachbothDualWiringHarnessfemaleleadstothetwobatteriesasdescribedabove.SeeTable3:
BatteryCalculations.