PUTCONFIG*
Description: Use this command to load the project file to the CLS-C6RF
Help Menu(s): File
Syntax: PUTCONFIG PROJECT
Parameters: PROJECT – The only valid parameter value
REBOOT
Description: Use this command to reboot the CLS-C6RF
Help Menu(s): Common
Syntax: REBOOT
Parameters: None
REPORTCRESNET
Description: Use this command to report devices on the local network
Help Menu(s): Common
Syntax: REPORTCRESNET <ID>
REPORTCRESNET ALL
Parameters: <03…FE> to identify a specific device
ALL – To show all devices on the network
RESTORE
Description: Use this command to set all project configuration and parameters to the factory default settings.
Help Menu(s): System
Syntax: RESTORE ALL
Parameters: ALL the only valid value for this parameter
RFCHANNEL*
Description: Display RF Channel
Help Menu(s): File
Syntax: RFCHANNEL
Parameters: display RF Channel
<CH|AUTO|DISABLE> set to fix channel <11..26>, auto channel, or disable rf
SYSTEM*
Description: Use this command to load firmware to the CLS-C6RF.
Help Menu(s): File
Syntax: SYSTEM
Parameters: None
UPLOAD*
Description: Use this command to load firmware to the slave device on the local network.
Help Menu(s): File
Syntax: UPLOAD <ID> FIRMWARE
Parameters: <03…FE>
FIRMWARE – the only valid value for this parameter
Operations Guide - DOC. 6418A iLux
Integrated Lighting System w/infiNET
: CLS-C6RF 45