that device will flash for one second to confirm that it has been assigned. The
bargraph for that group will also flash off for one second.
Go to a shade group and assign all channels. Then go to the next shade group
and assign those channels. Repeat for all shade groups. Note that a given shade
group can only have one type of shade controller (SDC, SDC-DC, or SSC). If a
shade controller of a given type is assigned to a group that already contains
shade controllers of the other type, the other controllers will be removed from
that group. Also, a given channel on a shade controller can only belong to a
single group. So if a shade controller that belongs to one group is assigned to a
new group, it will be removed from the first group. Therefore, if you
accidentally assign a shade controller to the wrong group, simply go to the
correct group and reassign it.
Once all shade controllers are assigned, press Save to save the assignments and
return to Standard mode, or press Cancel to discard the assignments.
Display/Set MNET ID Of This Unit (id)
If this unit is to be connected to a Cresnet control system network, you may have to
change its MNET ID. (When connected to another CLS-C6RF unit’s local network,
you do not want to set the ID – running Auto Discovery on the master device will do
this automatically, as will the Set ID process of the iLux Designer.)
To do this, enter Setup mode and scroll to the “id” option, using the ^ and v
buttons.
Press the up/down button. The display will show the current MNET ID. The id
mode is now locked. A dot will be shown to the right of the “id.” The display
will alternate between “id” and the current MNET ID.
Use the up/down button to adjust the ID up or down (03-FE).
If the button is held for more than ½ second, the unit will auto-repeat and start
scrolling through the values. At the upper or lower limit, the unit will pause for
½ second and then wrap around.
Press the Save button to save the new value and return to Standard mode. Press the
Cancel button to return to Standard mode without saving – the current MNET ID
will be retained.
NOTE: The valid address range is 03 – 20. If at any time the transceiver connection
is lost because the serial jack was inserted, the “E1” error code will be shown, the
Save led will turn off, and the Cancel led will turn on. The Cancel button can be
used to exit Setup and enter Standard mode.
Error Code:
“E1” = Cannot communicate with transceiver.
Acquire Gateway (Ac)
This procedure is used to acquire the C2N-MNETGW gateway.
To do this, enter Setup mode and scroll to the “Ac” option, using the ^ and v
buttons.
Press and hold the up/down button for five seconds. The Acquire mode will
start. The “Ac.” text will flash, the Cancel led will flash. The acquire process
may take up to five minutes.
Operations Guide - DOC. 6418A iLux
Integrated Lighting System w/infiNET
: CLS-C6RF 21