sensor timeout when the motion sensor function is enabled. You can also launch the
Crestron Engraver software program to create an engraver project for the CLS-C6RF
function buttons label.
NOTE: In systems with multiple CLS-C6RF units that have the motion sensor
function enabled, it is important to set the motion sensor timeout of each unit to the
same value.
Keypads
The Keypads screen allows you to add up to 16 remote keypads; specify the remote
keypad type; define the action type, action, and target of each button on that keypad.
You can also launch the Crestron Engraver to create an engraver project for each
remote keypad.
NOTE: All keypads defined in the project must be installed and present on the
CLS-C6RF network before setting Network IDs via the Finish screen.
Finish
The Finish screen allows you to send your iLux Designer project to the CLS-C6RF;
set the Net IDs for network devices; retrieve configuration information from the
current CLS-C6RF module; and print reports that give the spreadsheet data from
each of the configuration screens.
Console Command Settings
Enabling/disabling IR reception, resetting the brightness level for the white and
green LEDs, and resetting the Glow mode level can be done only via console
commands.
By default, IR reception is enabled, the white and green LED brightness levels are
set to 70 and 63, respectively, the white shift LED brightness level is set to 70, and
the white LED Glow mode level is set to 7. If the settings are acceptable, continue
with the configuring procedures. If these settings are not satisfactory, open the
Crestron Toolbox and click Tools | Text Console to display the “Text Console”
window, and follow the instructions given below.
IR Reception
1. At the iLux> prompt, type <IR> and press Return to display the current
setting. The system displays:
IR reception is enabled (or disabled)
iLux>
2. To disable IR reception, type <IR disable> and press Return. The system
displays:
IR reception is disabled
iLux>
3. To enable IR reception, type <IR enable> and press Return. The system
displays:
IR reception is enabled
iLux>