Crestron electronic CLS-C6RF Indoor Furnishings User Manual


 
iLux
Integrated Lighting System w/infiNET
Crestron CLS-C6RF
Setup Mode Mnemonics
TWO-DIGIT
DISPLAY
DESCRIPTION
Sc Scene Programming
Ld Setup lighting load Load types
LE Setup lighting load Low-End limits
HE Setup lighting load High-End limits
bF button Functions (i.e. recall scene, toggle scene, shades control, etc.)
ud Set function of up/down button
oc Setup occupancy Sensing
Ad Run Auto-discovery
AS Assign Shade groups
id Display or set the MNET id of this unit
Ac Acquire gateway
UA UnAcquire Gateway
Ch Display or set the RF Channel
Fd Restore Factory default
Er Error
Press the ^ or v buttons to scroll through this list of available setup options.
Once the desired setup option appears in the display, use the various buttons on
the CLS-C6RF to make adjustments, as described on the following pages.
Once any adjustment is made, Setup mode is now “locked” into that particular
option (this is indicated by lighting the period at the end of the mnemonic).
Once locked in an option, the ^ and v buttons will no longer scroll through the
options; you must exit setup before you can choose another option.
When the adjustments are complete, press Save to store the changes permanently,
and exit Setup mode, or press Cancel to exit Setup mode without saving the changes.
The unit reverts to Standard mode.
Scene Programming (Sc)
This setup option allows the user to adjust the scene parameters. This is another way
to accomplish scene changes as discussed in “Changing Scene Presets” on page 12.
This method also allows you to change the settings for scenes greater than scene 6.
Scenes can be turned off in addition to being recalled. When a scene is turned off,
only the lighting loads are turned off. If the scene contains any shades, they are not
affected. The fade time for turning the scene lights off is the same as for recalling the
scene. Therefore, no additional parameters need to be set to define the off behavior.
Select the scene to be changed using the up/down button. As you cycle through the
list of scenes, the lights and shades will not change, and the bargraphs will be off.
Set the lighting loads and shade positions for the scenes as discussed in “Changing
Scene Presets” on page 12. As you set the scenes, note the following:
When a lighting load reaches the HE (high end) limit, the lights will stop. The
two-digit display will continue to rise. If lights reach the LE (low end) limit, the
two-digit display will continue to go down, but lights will stay at the LE limit
until they reach Off—at which point they will turn off. If you save the scene
setting while the display is at a level below the LE limit, or above the HE limit,
the displayed value will be saved, but the light level will be limited to the
programmed limits.
iLux
Integrated Lighting System w/infiNET
: CLS-C6RF Operations Guide - DOC. 6418A
14