Uploading and Upgrading
Crestron recommends using the latest programming software and that each device
contains the latest firmware to take advantage of the most recently released features.
However, before attempting to upload or upgrade, it is necessary to establish
communication.
Establishing Communication
Use Crestron Toolbox for communicating with the CLS-C6RF; refer to the Crestron
Toolbox help file for details. There are two methods of communication
Direct Serial
Direct Serial Communication
The RS-232 mini phone jack port on the CLS-C6RF connects to the serial
port on the PC via the supplied serial cable.
Use the Address Book in Crestron Toolbox to create an entry using the
expected serial communication protocol (RS232, auto-detect baud rate, no
parity, 8 data bits, 1 stop bit, XON/XOFF disabled, RTS/CTS disabled).
Display the CLS-C6RF’s “System Info” window (click the
icon);
communications are confirmed when the device information is displayed.
Indirect Serial
Indirect Serial Communication
The CLS-C6RF connects to the C2N-MNETGW gateway via infiNET; the
gateway connects to the control system via Cresnet.
Establish communications between the PC and the control system as
described in the latest version of the 2-Series Reference Guide (Doc. 6256).
Operations Guide - DOC. 6418A iLux
Integrated Lighting System w/infiNET
: CLS-C6RF 31