VideoJet 8008 / VideoJet 8004 | Installation and Operating Manual
EN | 91
Bosch Security Systems | 2006-07 | V1.5 Configuration using a Web browser
This segment in the partition functions in a similar manner to a ring buffer and is
overwritten until an alarm is actually triggered. Recording occurs on the segment
only for the duration of the preset post-alarm time and a new segment subse-
quently used in the same manner.
This ensures that the alarm recorded is always secured for its entire duration
and the space required to save each alarm recording is easy to calculate.
Number of alarm tracks:
Select the number of alarm tracks to be used in the partition. One alarm event
can be recorded in each alarm track. Accordingly, the number of alarms entered
can be recorded and archived. A partition can contain a maximum of 128 alarm
recordings.
If the Ring mode option (see page 93) is set for the partition, the latest alarm
recordings are always saved in the preset number. If the Linear mode option is
set for the partition, the recording stops as soon as all the alarm tracks have
been written.
Pre-alarm duration:
Select the period to be covered by pre-alarm recording.
Post-alarm duration:
Select the period to be covered by alarm recording.
Used alarm tracks on partition:
This displays how many of the alarm tracks created have already been used.
Used space on partition:
This displays how much space is already used in the partition.
Free space on partition:
This displays how much space is still available in the partition.
Recording status:
The graphic indicates the recording activity in this partition. You will see an ani-
mated graphic while recording is taking place.