VideoJet 8008 / VideoJet 8004 | Installation and Operating Manual
EN | 103
Bosch Security Systems | 2006-07 | V1.5 Configuration using a Web browser
Relay follows:
If required, select a specific event that will trigger the relay. The following events
are possible triggers:
❚ Off
Relay is not triggered by events
❚ Connection
Trigger whenever a connection is made
❚ Video alarm 1
Trigger by interrupting the video signal at the Video 1 input
❚ Motion 1
Trigger by motion alarm at Video 1 input
❚ Local input 1
Trigger by external alarm input 1
❚ Remote input 1
Trigger by remote station's switching contact (only if a connection exists)
Relay name:
You can assign a name for the relay here. The name is shown on the button next
to Trigger relay. The Livepage can also be configured to display the name
under the relay icon.
Trigger relay:
Click the button to trigger the relay manually (for testing or to operate a door
opener, for example).