Bosch Appliances 8004 Home Security System User Manual


 
Installation and Operating Manual | VideoJet 8008 / VideoJet 8004
EN | 144
Appendix Bosch Security Systems | 2006-07 | V1.5
RS232/485 interface
Options for using the serial interface include transferring transparent data, con-
trolling connected units or operating the unit with a terminal program. Depending
on the setting, the serial interface uses the RS232 or RS422/485 standards. The
standard that is used depends on the current configuration (see pages 60 and
104).
RJ45 socket pin assignment
The pin assignment depends on the standard used.
Contact RS232 standard RS422/485 standard
1 RxD (receive data) RxD+ (receive data plus)
2 CTS (clear to send) RxD- (receive data minus)
3–
4–
5 GND (ground) GND (ground)
6–
7 TxD (transmit data) TxD- (transmit data minus)
8 RTS (ready to send) TxD+ (transmit data plus)