Bosch Appliances 8004 Home Security System User Manual


 
VideoJet 8008 / VideoJet 8004 | Installation and Operating Manual
EN | 21
Bosch Security Systems | 2006-07 | V1.5 Installation
Data interface
The bidirectional data interface is used to control connected units, such as a
dome camera with motorized lens. The range of controllable equipment is
expanding constantly. The manufacturers of the relevant equipment provide
specific information on installation and control.
The
RS232/485
connection supports the RS232, RS422 and RS485 transmission
standards. The serial interface is designed as a RJ45 socket. See
page
144 for
the pin assignment.
Caution
Please take note of the appropriate documentation when installing and op-
erating the unit to be controlled. The documentation contains important
safety instructions and information about permitted uses.
Note
A video connection is necessary to transmit transparent data.
Network
You can connect the unit to a 10/100/1000 Base-T network using a standard
UTP category 5 cable with RJ45 connectors.
Connect the unit to the network via the 10/100/1000 MBit Base-T socket.
Alarm inputs
VideoJet 8008 and VideoJet 8004 offer ten alarm inputs via an orange terminal
block. The alarm inputs are used to connect to external alarm devices such as
door contacts or sensors. When configured appropriately, an alarm device can,
for example, trigger the unit to automatically establish a connection with a
remote station.
A zero potential make contact or switch can be used as the actuator. You can
find the pin assignment on page 146.
Note
If possible, use a bounce-free contact system as the actuator.
Connect the lines to the appropriate terminals of the orange terminal block
and check that the connection is secure.