Xantrex Technology Freedom SW Series Home Security System User Manual


 
Configuration
3–14 975-0704-01-01 Revision A
Control Panel
In the control panel, adjust the following settings as needed, and click the close
button when done.
Select Enable to turn on the inverter. When the
inverter is on, any AC loads connected to it receive
power. Select Disable to turn off the inverter.
If there are two inverter/chargers in the system, this
setting applies to both devices.
Select Auto to automatically start or stop the
generator based on the settings selected in the
Xanbus AGS. These settings include triggers for low
battery voltage, AC loads on the inverter, thermostat
triggers and exercise time.
Select Manual On to override the automatic start
settings and start the generator. The generator will
run until manually stopped (Manual Off) or when it
reaches the Maximum Run Time setting defined in
the AGS.
Select Manual Off to override the automatic stop
settings and stop the generator when it has been
started manually (Manual On).
For information on AGS settings see the Xanbus
Automatic Generator Start Owner’s Guide.
Select the appropriate time and time zone from the
list to synchronize the ComBox and Xanbus SCP
internal clocks.
It is important for devices on the Xanbus network to
have the same system time. If the internal clocks are
not synchronized, timing-reliant devices such as the
AGS could start or stop unintentionally.
Note: This setting also sets the time and zone value
in the Settings screen. See “Changing Advanced
Conext ComBox Settings” on page 3–15.