Floor heat doesn’t work or will not hold constant.
There are two sets of floor temperature controls: one for the left
side and one for the right. Make sure you are operating the correct
set of controls.
First: Make sure the temperature control knob is set to a higher-
than-ambient temperature.
Second: Press the on/off button several times and make sure the
amber light in the switch comes on. If the temperature control knob
is set to a higher-than-ambient temperature, the system light should
also come on. If the system light does not come on, it is a strong
hint that a deeper problem exists in the system.
Third: Check the fuse for the system and make sure it hasn’t
blown. Replace it if necessary. Refer to Replacing Floor Tempera-
ture Fuses on Page 61.
CAUTION: Before working on the electrical system,
make sure the unit is Off and the electric power cord
un-plugged.
Fourth: Check all wire connections behind the controls.
Fifth: If none of the above fix the problem, you probably have a
defective floor temperature controller. Replace the floor tempera-
ture controller. Order P/N 853844 and refer to Page 109 for
replacement instructions.
Sixth: If this does not fix the problem, you probably have a bad
heating pad. This problem cannot be fixed in the field. Return the
unit to SSCI for repairs. Refer to Returning the Intensive Care
Unit for Repairs on Page 138.