Chapter 5 - Repairs & Replacements
Panel, Filter/Fans,
Complete
P/N 206874
Procedure
1. Turn all four panel access knobs (Figure 149) one-quarter
turn counter-clockwise and pull the old panel completely
off the Intensive Care Unit.
2. Look at the rear of the new access panel (Figure 150) and
make sure that the locking arms on all four access knobs
are vertical. Note: The locking arms on the right should
point down, and that the arms on the left should point up.
3. Seat the panel in place over the filter/fans compartment
opening, and turn all four panel knobs one-quarter turn
clockwise to lock the panel in place. Note: It is a good
idea to tug gently on one of the access knobs to be sure the
panel is secure.
Figure 149. Filter/Fans Compartment
Access Knobs
Access
Knobs
Note: If the digital readout from the old filter/fans compartment
panel is working OK, it can be dis-mounted from the panel and
used in some other way, or kept as a spare.
Figure 150. Inside of Filter/Fans
Compartment Panel
To close
panel, latch
arms on this
side must
point down.
To close
panel, latch
arms on this
side must
point up.