Suburban Mfg 12019-01-NGFREP Air Conditioner User Manual


 
98 SSCI - Suburban Surgical Company, Inc.
Chapter 5 - Repairs & Replacements
Circuit Breaker
P/N 853466
Two identical 10 amp. circuit breakers are located on the electronics
compartment door. The left breaker (viewed from the front) protects
the cooling system. The right breaker protects the remainder of the unit.
Both circuit breakers are removed and installed the same way.
CAUTION: Before proceeding, make sure the unit is
Off, and the electric power cord un-plugged.
Tool Required
Small flat-blade screwdriver
Removal
1. Make sure that the main on/off switch is Off and the
amber light in the switch is out.
2. Unplug the power cord from the electrical outlet.
3. Open the electronics compartment (refer to Page 57).
4. Pull the two spade connectors off the rear of the circuit
breaker (Figure 111). Note: The breaker for the cooling
system has three wires; the other breaker has only two.
5. With a small flat-blade screwdriver, pry the
retaining ring from the circuit breaker.
6. Pull the circuit breaker out through the front
of the door.
Installation
1. Slide the new circuit breaker into the door
from the front.
2. Place the new retaining ring (supplied) onto
the rear of the breaker and push it all the
way to the front to hold the breaker firmly
in place.
Figure 111. Rear View of Circuit
Breakers
Cooling
System
Breaker
Unit
Circuit
Breaker
Retaining
Ring