Suburban Mfg 12019-01-NGFREP Air Conditioner User Manual


 
Form No. 702718 Rev. A March, 2005 105
Owner’s Manual - Regal Intensive Care Unit
Digital Display
(Floor Temperature,
Left & Right)
P/N 853843
There are two digital displays on the electronics compartment door,
one each for left floor temperature and right floor temperature. The
displays are identical and are removed and installed the same way.
CAUTION: Before proceeding, make sure the unit is
Off, and the electric power cord un-plugged.
Tool Required
13/64-in. wrench
Removal
1. Make sure that the main on/off switch is Off and the
amber light in the switch is out.
2. Unplug the power cord from the electrical outlet.
3. Open the electronics compartment (refer to Page 57).
4. Pull the 4-wire ribbon connector off the rear of the display
(Figure 117).
5. With a 13/64-in. wrench, remove the four retaining nuts on
the rear of the digital display.
Figure 117. Inside View of Digital Display
Assembly
4-Wire Ribbon Connector
Retaining Nut (1 of 4)
Red
stripe on
this wire
Figure 118. Digital Display Parts
Bezel
Nuts
Ribbon
Cable
Printed
Circuit Board