Form No. 702718 Rev. A March, 2005 117
Owner’s Manual - Regal Intensive Care Unit
7. Rotate the knurled ring on the audible alarm counter-
clockwise until it comes off (Figure 134).
8. Pull the audible alarm from the rear of the compartment door.
Installation
1. Unscrew the knurled ring from the new audible alarm
(Figure 134).
2. From the rear of the compartment panel, insert the audible
alarm into its opening.
3. Secure the alarm in place by screwing on the knurled ring.
4. Re-connect the wires to the terminals on the alarm
(Figure 133).
5. Close and secure the electronics compartment door.
6. Plug the power cord into its wall outlet.
Figure 132. Inside View - Audible Alarm
Negative (-)
Terminal
Positive (+)
Terminal
Figure 134. Outside View - Audible Alarm
Knurled
Ring