Programming Manual - Basic & Applied Instruction Edition
A Programming Tool Applicability and Version Upgrade History
A-3 Version Upgrade History
31
FNC277-FNC279
Data
Transfer 3
32
FNC280-FNC289
High-Speed
Processing 2
33
FNC290-FNC299
Extension File
Register Control
34
FNC300-FNC305
FX
3U
-CF-ADP
35
SFC•STL
Programming
36
Interrupt
Function
37
Special Device
38
Error Code
A
Version Up
Information
B
Execution Times
Appendix A-3-5 Version upgrade history [FX3GC]
For the manufacturer’ serial number check method, refer to Appendix A-3-1.
Appendix A-3-6 Version upgrade history [FX3U]
For the manufacturer’ serial number check method, refer to Appendix A-3-1.
Appendix A-3-7 Version upgrade history [FX3UC]
Version
Manufacturer’s
serial number
Contents of version upgrade
Ver. 1.40
121****
(January, 2012)
First product
Corresponds to FX3G PLC Ver. 1.40.
Ver. 2.00
124****
(April, 2012)
Supports the following functions of the FX3U-16CCL-M:
- Network parameter
- Accessing the other station from CC-Link
- Remote device station initialization procedure registration
- CC-Link diagnostics
Special parameter error (M8489 and D8489) is added.
Ver. 2.10 134**** (April, 2013) Supports the IP address change function of Ethernet adapter.
Version
Manufacturer’s
serial number
Contents of version upgrade
Ver. 2.20
55****
(May, 2005)
First product (supporting the functions described as "Ver. 2.20 or later" in this manual)
Corresponds to FX3UC PLC Ver. 2.20.
Ver. 2.30
5Y****
(November, 2005)
Adding the following instructions and function up.
- Adding MEP and MEF instructions
- Function up of MUL (FNC 22), DIV (FNC 23), and RS2 (FNC 87) instructions
Ver. 2.40
74****
(April, 2007)
Supports the following instructions:
ADPRW (FNC276)
Ver. 2.41
7Y****
(November, 2007)
The baud rate "38400 bps" is supported in the RS and RS2 instructions, inverter
communication and computer link.
Ver. 2.61
97****
(July, 2009)
Supports following 6 instructions:
FLCRT (FNC300), FLDEL (FNC301), FLWR (FNC302), FLRD (FNC303),
FLCMD (FNC304), FLSTRD (FNC305)
Supports connection of following special adapters:
-FX3U-3A-ADP
-FX3U-CF-ADP
Supports the hardware error function of FX3U-4DA-ADP.
Customer keyword / permanent PLC lock is supported.
Ver. 2.70
107****
(July, 2010)
Supports the following 3 instructions:
VRRD (FNC85), VRSC (FNC86), IVMC (FNC275)
Supports connection of following analog volume expansion board:
-FX3U-8AV-BD
Supports the lower over-scale detection function of FX3U-4AD-ADP and FX3U-3A-ADP.
Ver. 3.00
115****
(May, 2011)
Supports storage of symbolic information.
Support of the setting "Read-protect the execution program" for block passwords.
Special block error condition (D8166) is added.
Supports connection of following memory cassette.
-FX3U-FLROM-1M
Ver. 3.10
11Y****
(November, 2011)
Supports the following functions of the FX3U-16CCL-M:
- Network parameter
- Accessing the other station from CC-Link
- Remote device station initialization procedure registration
- CC-Link diagnostics
Special parameter error (M8489 and D8489) is added.
Version
Manufacturer’s
serial number
Contents of version upgrade
Ver. 1.00
41****
(January, 2004)
First product
Ver. 1.20
44****
(April, 2004)
Supports connection of the following special analog adapters:
-FX3U-4AD-ADP
-FX
3U-4DA-ADP
Ver. 1.30
48****
(August, 2004)
Supports connection of the following special analog adapters:
-FX3U-4AD-PT-ADP
-FX
3U-4AD-TC-ADP
Supports connection of the following special function block:
-FX3UC-4AD
Supports the following 3 instructions:
- SCL2 (FNC269), RWER (FNC 294), and INITER (FNC 295)
Adds function of the following instruction: