Mitsubishi Electronics FX3GC Garage Door Opener User Manual


 
905
FX3S/FX3G/FX3GC/FX3U/FX3UC Series
Programming Manual - Basic & Applied Instruction Edition
A Programming Tool Applicability and Version Upgrade History
A-1 Programming Tool Applicability
31
FNC277-FNC279
Data
Transfer 3
32
FNC280-FNC289
High-Speed
Processing 2
33
FNC290-FNC299
Extension File
Register Control
34
FNC300-FNC305
FX
3U
-CF-ADP
35
SFC•STL
Programming
36
Interrupt
Function
37
Special Device
38
Error Code
A
Version Up
Information
B
Execution Times
Japanese version
*1. Write during RUN is not possible with a SFC program.
*2. Write during RUN is not possible with a list program or a SFC program.
Programming tool PLC Version Remarks
GX Works2
*1
(SWDNC-GXW2-J)
FX3S Ver. 1.492N or later
Writing in the instruction and device ranges during RUN is supported in FX3S
PLC earlier than Ver. 1.00.
FX3G/FX3GC
Ver. 1.07H or later
Writing in the instruction and device ranges during RUN is supported in FX3G
PLC earlier than Ver. 1.40.
Ver. 1.77F or later
Writing in the instruction and device ranges during RUN is supported in FX3G
and FX3GC PLCs earlier than Ver. 1.40.
FX3U/FX3UC
Ver. 1.07H or later
Writing in the instruction and device ranges during RUN is supported in FX3U and
FX3UC PLCs earlier than Ver. 2.70.
Ver. 1.45X or later
Writing in the instruction and device ranges during RUN is supported in FX3U and
FX3UC PLCs Ver. 2.70.
GX Developer
*2
(SWD5C-GPPW-J)
FX
3G
Ver. 2.00A or later
Writing in the instruction and device ranges during RUN is supported in FX2N
PLC Ver. 1.00.
Ver. 5.00A or later
Writing in the instruction and device ranges during RUN is supported in FX1N
PLC Ver. 1.00.
Ver. 8.72A or later
Writing in the instruction and device ranges during RUN is supported in FX
3G
PLC earlier than Ver. 1.10.
Ver. 8.76E or later
Writing in the instruction and device ranges during RUN is supported in FX3G
PLC Ver. 1.10.
FX3U/FX3UC
Ver. 7.00A or later
Writing in the instruction and device ranges during RUN is supported in FX
2N
PLC Ver. 3.00.
Ver. 8.13P or later
Writing in the instruction and device ranges during RUN is supported in FX3UC
PLC earlier than Ver. 1.30.
Ver. 8.18U or later
Writing in the instruction and device ranges during RUN is supported in FX3UC
PLC earlier than Ver. 2.20.
Ver. 8.23Z or later
Writing in the instruction and device ranges during RUN is supported in FX3U and
FX3UC PLCs earlier than Ver. 2.30.
Ver. 8.29F or later
Writing in the instruction and device ranges during RUN is supported in FX3U and
FX3UC PLCs earlier than Ver. 2.61.
Ver. 8.82L or later
Writing in the instruction and device ranges during RUN is supported in FX3U and
FX3UC PLCs Ver. 2.61.
FX-PCS/WIN
*2
FX3G Ver. 4.00 or later
Writing in the instruction and device ranges during RUN is supported in FX1N
PLC Ver. 1.00.
FX3U/FX3UC
Ver. 1.00 or later
Writing in the instruction and device ranges during RUN is supported in FX2 PLC
Ver. 3.30.
Ver. 2.00 or later
Writing in the instruction and device ranges during RUN is supported in FX2N
PLC Ver. 1.00.
Ver. 4.20 or later
Writing in the instruction and device ranges during RUN is supported in FX2N
PLC Ver. 3.00.