Mitsubishi Electronics FX3GC Garage Door Opener User Manual


 
837
FX3S/FX3G/FX3GC/FX3U/FX3UC Series
Programming Manual - Basic & Applied Instruction Edition
37 Operation of Special Devices (M8000 -, D8000 -)
37.1 Special Device List (M8000 -, D8000 -)
31
FNC277-FNC279
Data
Transfer 3
32
FNC280-FNC289
High-Speed
Processing 2
33
FNC290-FNC299
Extension File
Register Control
34
FNC300-FNC305
FX
3U
-CF-ADP
35
SFC•STL
Programming
36
Interrupt
Function
37
Special Device
38
Error Code
A
Version Up
Information
B
Execution Times
Timing Clock (Refer to Section 24.3 for details.) and Positioning [FX
3S
/FX
3G
/FX
3GC
/FX
3U
/FX
3UC
]
(Refer to Positioning Control Edition for
details.)
[M]8330
DUTY (FNC186) instruction: Timing clock
output 1
*1
D8330–––––
[M]8331
DUTY (FNC186) instruction: Timing clock
output 2
*1
D8331–––––
[M]8332
DUTY (FNC186) instruction: Timing clock
output 3
*1
D8332–––––
[M]8333
DUTY (FNC186) instruction: Timing clock
output 4
*1
D8333–––––
[M]8334
DUTY (FNC186) instruction: Timing clock
output 5
*1
D8334–––––
[M]8335 Not used –––––
M 8336
*2
DVIT (FNC151) instruction:
Interrupt input specification function enabled
*3
D8336–––––
[M]8337 Not used –––––
M 8338
*2
PLSV (FNC157) instruction:
Acceleration/deceleration operation
*1
–––––
[M]8339 Not used –––––
[M]8340
[Y000] Pulse output monitor
(ON: BUSY/ OFF:
READY)
–––––
M 8341
*2
[Y000] Clear signal output function enable –––––
M 8342
*2
[Y000] Zero return direction specification –––––
M 8343 [Y000] Forward limit –––––
M 8344 [Y000] Reverse limit –––––
M 8345
*2
[Y000] DOG signal logic reverse –––––
M 8346
*2
[Y000] Zero point signal logic reverse –––––
M 8347
*2
[Y000] Interrupt signal logic reverse –––––
[M]8348 [Y000] Positioning instruction activation –––––
M 8349
*2
[Y000] Pulse output stop command –––––
[M]8350
[Y001] Pulse output monitor
(ON: BUSY/ OFF:
READY)
–––––
M 8351
*2
[Y001] Clear signal output function enable –––––
M 8352
*2
[Y001] Zero return direction specification –––––
M 8353 [Y001] Forward limit
–––––
M 8354 [Y001] Reverse limit
–––––
M 8355
*2
[Y001] DOG signal logic reverse –––––
M 8356
*2
[Y001] Zero point signal logic reverse –––––
M 8357
*2
[Y001] Interrupt signal logic reverse –––––
[M]8358 [Y001] Positioning instruction activation –––––
M 8359
*2
[Y001] Pulse output stop command –––––
[M]8360
[Y002] Pulse output monitor
(ON: BUSY/ OFF:
READY)
–––––
M 8361
*2
[Y002] Clear signal output function enable –––––
M 8362
*2
[Y002] Zero return direction specification –––––
M 8363 [Y002] Forward limit –––––
M 8364 [Y002] Reverse limit –––––
M 8365
*2
[Y002] DOG signal logic reverse –––––
M 8366
*2
[Y002] Zero point signal logic reverse –––––
M 8367
*2
[Y002] Interrupt signal logic reverse –––––
[M]8368 [Y002] Positioning instruction activation –––––
M 8369
*2
[Y002] Pulse output stop command –––––
*1. Available in Ver. 2.20 or later.
*2. Cleared when the PLC switches from RUN to STOP.
*3. Available in the Ver. 1.30 or later.
Number and
name
Operation and function
Applicable model
FX
3S
FX
3G
FX
3GC
FX
3U
FX
3UC
Correspond-
ing special
device
FX
1S
FX
1N
FX
1NC
FX
2N
FX
2NC