Lucent Technologies SLV 9124 Window User Manual


 
Configuration
3-59
9124-A2-LB20-00
March 2000
Configuring SNMP Traps and Trap Dial-Out
Select SNMP Traps from the Management and Communication menu to
configure SNMP traps and dial-out when a trap is generated (see Table 3-16).
Main Menu Configuration Management and Communication
SNMP Traps
See Appendix B, SNMP MIBs and Traps, and RMON Alarm Defaults, for trap
format standards and special trap features, including RMON-specific traps, and
the default settings that will generate RMON-specific SNMP traps.
Table 3-16. SNMP Traps and Trap Dial-Out Options (1 of 4)
SNMP Traps
Possible Settings: Enable, Disable
Default Setting: Disable
Determines whether the FrameSaver unit sends trap messages to the currently
configured SNMP trap manager(s).
Enable Sends trap messages.
Disable Does not send trap messages.
Number of Trap Managers
Possible Settings: 1 6
Default Setting: 1
Specifies the number of SNMP management systems that will receive SNMP trap
messages from the FrameSaver unit. An NMS IP Address must be configured in the
NMS n IP Address configuration option for each trap manager to receive trap
messages.
1 6 Specifies the number of trap managers (inclusive).
NMS n IP Address
Possible Settings: 001.000.000.000 223.255.255.255, Clear
Default Setting: Clear (000.000.000.000)
Specifies the IP address that identifies the SNMP manager(s) to receive SNMP traps.
Display Conditions This option appears for each trap manager specified in the
Number of Trap Managers configuration option.
001.000.000.000 223.255.255.255 Adds to or changes the IP address for the trap
manager.
Clear Fills the NMS IP address with zeros.