Lucent Technologies SLV 9124 Window User Manual


 
Configuration
3-48
9124-A2-LB20-00
March 2000
Setting Up Management and Communication Options
The following options can be selected from the Management and Communication
menu:
H Node IP Options
H Management PVC Options
H General SNMP Management Options
H Telnet and FTP Sessions Options
H SNMP NMS Security Options
H SNMP Traps and Trap Dial-Out Options
H Communication Port Options
H External Modem (COM Port) Options
Configuring Node IP Information
Select Node IP to display, add, or change the information necessary to support
general IP communications for the node (see Table 3-11). When deploying units
to remote sites, minimally configure the Node IP Address and Subnet Mask.
Main Menu Configuration Management and Communication Node IP
This set of configuration options includes a Troubleshooting (TS) Management
Link feature to help service providers isolate device problems within their
networks. This feature allows Telnet or FTP access to the unit on this link.
Troubleshooting over this link is essentially transparent to customer operations.
No alarms or SNMP traps are generated to create nuisance alarms for the
customer.
TS_Management_Link is initially disabled in most models, but the link can be
enabled at any time. Any valid network Management PVC created on a standard
DLCI can be used. When enabled, a troubleshooting link can be accessed any
time the service provider requests access. An assigned security level can also
control access.
When a DLCI has been defined as the troubleshooting management link, the
link is identified in the status field at the bottom of the Management PVC Entry
screen with the This PVC has been designated as the TS
Management Link message.
NOTE:
The unit may come from the factory with a TS Management PVC already
set up (e.g., 980).