Troubleshooting
6-8
9124-A2-LB20-00
March 2000
Table 6-1. Alarm Conditions (2 of 6)
Alarm Condition What To DoWhat It Indicates
DLCI nnnn Down,
frame relay link
1,2
The DLCI for the specified
frame relay link is down.
Verify that the network LMI is up.
If it is, contact your network
service provider.
DTR Down from
Port-1 Device
The DTR control lead on
the device connected to the
specified port is off. This
message applies to data
ports that act as DCEs.
Examine the attached DTE and
cable connected to the system’s
port.
H Check that the port cable is
securely attached at both
ends.
H Check the status of the
attached equipment.
Link Down
Administratively,
frame relay link
2
The specified frame relay
link has been disabled by
the unit due to LMI
Behavior conditions or LMI
Protocol on another link is
in a failed state.
This is not an alarm
condition so System
Operational appears,
as well.
Verify that the network LMI is up.
If it is, contact your network
provider.
1
nnnn indicates a DLCI number of 16 through 1007.
2
frame relay link is one of the following:
– Net1-FR1. The frame relay link specified for the network interface, Network 1.
– Port-1. The frame relay link associated with the user data port.