Lucent Technologies SLV 9124 Window User Manual


 
Configuration
3-23
9124-A2-LB20-00
March 2000
Table 3-3. General System Options (2 of 2)
Secondary Clock Source
Possible Settings: Net1, DSX, Internal
Default Setting: Internal
Provides a secondary clock source when the primary clock source fails. The source
selected for this configuration option provides all of the timing within the unit and the
clocks for all of the external interfaces.
The clock source will switch back to primary when the primary clock source returns and
is stable for 10 seconds. If the secondary clock source fails, the clock source will switch
to internal. The clock source will switch back to primary when the primary clock source
returns and is stable for 10 seconds.
NOTE: For the Primary and Secondary Clock Source options, only Internal can be
selected for both options. All other selections must have different settings
(e.g., if Primary Clock Source is set to Net1, Secondary Clock Source
cannot be set to Net1).
Net1 The secondary clock is derived from the Network1 T1 interface.
DSX The secondary clock is derived from the DSX-T1 interface. This setting only
appears if the DSX-1 interface is installed and enabled (see Configuring the DSX-1
Interface).
Internal The secondary clock is the internal clock.