Lucent Technologies SLV 9124 Window User Manual


 
Troubleshooting
6-10
9124-A2-LB20-00
March 2000
Table 6-1. Alarm Conditions (4 of 6)
Alarm Condition What To DoWhat It Indicates
LOS at DSX-1 A Loss of Signal (LOS)
condition is detected on the
DSX-1 interface. Clears
when the ratio of ones to
zeros received is greater
than or equal to 12.5%.
H DSX-1 cable problem.
H No signal being
transmitted from the
DTE.
H Check that the DSX-1 cable is
securely attached at both
ends.
H Check the DTE status.
LOS at Network 1 A Loss of Signal (LOS)
condition is detected on the
network interface. Clears
when the ratio of ones to
zeros received is greater
than or equal to 12.5%.
H Network cable problem.
H No signal is being
transmitted at the far-end
FrameSaver unit.
H T1 facility problem.
H Check that the network cable
is securely attached at both
ends.
H Check far-end FrameSaver
unit status.
H Contact your network provider.
Network Com Link
Down
The communication link for
the COM port is down and
the COM port is configured
for Net Link.
Check the router connected to
the COM port.
OOF at DSX-1 An Out of Frame (OOF)
condition is detected on the
DSX-1 interface.
H Incompatible framing
format between the DTE
and the FrameSaver
unit.
H DSX-1 cabling problem.
H Check that the framing format
for the DSX-1 (DTE) interface
is correct.
H Check that the DSX-1 cable is
securely attached at both
ends.