Operation and Maintenance
5-3
9124-A2-LB20-00
March 2000
Viewing LEDs and Control Leads
The FrameSaver 9124 unit’s faceplate includes LEDs (light-emitting diodes) that
provide status on the unit and its interfaces.
99-15821-02
9124
OK
ALM
TST
SIG
OOF
ALM
SIG
OOF
ALM
OK
NETWORK DSX PORT
FrameSaver
®
SLV
The Display LEDs and Control Leads screen allows you to monitor a remote unit
and is useful when troubleshooting control lead problems. The appropriate
interfaces are shown on this screen, with the appropriate status highlighted.
Main Menu →Status →Display LEDs and Control Leads
Display LEDs & Control Leads Screen
main/status/leds 9124-II
Device Name: Node A 5/26/1999 23:32
DISPLAY LEDS & CONTROL LEADS
GENERAL
NETWORK1 DSX-1 PORT-1
OK Sig Sig OK
Alarm OOF OOF TXD
Test Alm Alm RXD
DTR
CTS
–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
ESC for previous menu M
ainMenu Exit
R
efresh
Refresh the screen to view control lead transitions. LED and control lead
descriptions are in the sections that follow.