Lucent Technologies SLV 9124 Window User Manual


 
Troubleshooting
6-22
9124-A2-LB20-00
March 2000
Physical Tests
A FrameSaver 9124 units physical tests screen for the network interface is
shown below.
Main Menu Test [Network Physical Tests/Data Port Physical Tests/
DSX-1 Physical Tests]
Physical Tests Screen Example
main/test/network 9124-II
Device Name: Node A 5/26/1999 23:32
NETWORK 1
PHYSICAL TESTS
Test Command Status Results
Local Loopbacks
Line Loopback: Start Inactive 0:00:00
Payload Loopback: Start Inactive 0:00:00
Repeater Loopback: Start Inactive 0:00:00
Remote Loopbacks
Send Line Loopback: Down
Send Inactive 0:00:00
Pattern Tests
Send: user-defined
0a0a Stop Active 0:00:00 - Errors 99999+
Monitor: user-defined
0a0a Stop Active 0:00:00 - Errors 99999+
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
Ctrl-a to access these functions, ESC for previous menu M
ainMenu Exit
I
njectErr ResetMon
The ResetMon function key at the bottom of the screen only appears when a
Monitor 511 test pattern is Active. Select R
esetMon to reset the monitor pattern
error counter.
CAUTION:
You should not run these tests with frame relay equipment attached;
you must disconnect the frame relay equipment and use external test
equipment.