Lucent Technologies SLV 9124 Window User Manual


 
SNMP MIBs and Traps, and RMON Alarm Defaults
B-21
9124-A2-LB20-00
March 2000
Table B-12. Static DLCI Alarm Defaults NetScout Area (2 of 2)
Item
Falling
Threshold
Default
Rising
Threshold
Default
Event
Type
IntervalMIB/Tag/OID
2
Sample
Type
1
Tx CIR Utilization D MIB: FR DTE MIB
(RFC 2115)
Tag: frCircuitSentOctets
OID: .1.3.6.1.2.1.10.32.2.1.
7.I.D
60 secs
(1 min)
None Must be
configured.
0
1
D = Delta. Indicates that the calculated difference between the current value and the previous value is contained
in the MIB.
A = Absolute. Indicates that the exact value for the item is contained in the MIB.
2
I in the OID = Interface ID of the frame relay link.
D = DLCI number.
Table B-13. Dynamic DLCI Alarm Defaults NetScout Area
Item
Sample
Type
1
MIB/Tag/OID
2
Interval
Event
Type
Rising
Threshold
Default
Falling
Threshold
Default
Rx DLCI Link
Utilization
D MIB: FR DTE MIB
(RFC 2115)
Tag: frCircuitReceivedOctets
OID: .1.3.6.1.2.1.10.32.2.1.
9.I.D
60 secs.
(1 min)
Rising 70% of link
capability
65% of link
capability
Tx DLCI Link
Utilization
D MIB: FR DTE MIB
(RFC 2115)
Tag: frCircuitSentOctets
OID: .1.3.6.1.2.1.10.32.2.1.
7.I.D
60 secs.
(1 min)
Rising 70% of link
capability
65% of link
capability
1
D = Delta. Indicates that the calculated difference between the current value and the previous value is contained
in the MIB.
A = Absolute. Indicates that the exact value for the item is contained in the MIB.
2
I in the OID = Interface ID of the frame relay link.
D = DLCI number.