Lucent Technologies SLV 9124 Window User Manual


 
Setting Up NetScout Manager Plus for FrameSaver Devices
8-5
9124-A2-LB20-00
March 2000
Verifying Domains and Groups
"
Procedure
1. From the NetScout Manager Plus main window, with the FrameRelay and
Admin radio buttons still selected, click on the Config Manager icon to open
the Configuration Manager main window.
2. Verify that only FrameSaver SLV-supported domains appear listed in the
Domain column. FrameSaver SLV-supported domains include:
ATALK IPX RMON
DECNET NETB SNA
IP NET~ VINES
IPV6 OSI
3. Verify that:
S (statistics collection) appears for each domain listed in the Group
column.
H (hosts) appears for the IP domain only.
Dashes occupy all other positions under the Group column.
Zeros appear under the Samples and Interval SH and LH columns.
Dashes appear under all Logging columns: Stat, Host, Conv.
4. If all these requirements are met, no further action is required. Close the
Configuration Manager window.
If all these requirements are not met, a FrameSaver SLV-supported domain
needs to be added, or if an unsupported domain needs to be deleted, the
Properties File must be edited.