Figure 4-8 HP ProLiant DL580 G5 Server Rear View
The callouts in the figure enumerate the following:
1. The iLO Ethernet port is used for the connection to the Console Switch.
2. NIC1 is used for the connection to the Administration Switch (branch or root).
3. NIC2 is used for the connection to the external network.
Setup Procedure
Perform the following procedure from the iLO Setup Utility for each HP ProLiant DL580 G5
node in the HP XC system:
1. Use the instructions in the accompanying HP ProLiant hardware documentation to connect
a monitor, mouse, and keyboard to the node.
2. Turn on power to the node. Watch the screen carefully during the power-on self-test, and
press the F8 key when prompted to access the Integrated Lights Out Setup Utility.
3. Make the iLO settings listed in Table 4-15 for each node in the hardware configuration.
Table 4-15 iLO Settings for HP ProLiant DL580 G5 Nodes
Set to This ValueOption Name
Submenu
NameMenu NameName
Create a common iLO user name and
password for every node in the hardware
configuration. The password must have a
minimum of 8 characters by default, but
this value is configurable.
The user Administrator is predefined
by default, but you must create your own
user name and password. For security
purposes, HP recommends that you delete
the Administrator user.
You must use this user name and password
to access the console port.
NewUserAdministration
On
DHCP EnableDNS/DHCPNetwork
115200 (Press the F10 key to save the
setting.)
Serial CLI
Speed
(bits/seconds)
CLISettings
4. Select FileExit to exit the Integrated Lights Out Setup Utility and resume the power-on
self-test.