HP (Hewlett-Packard) 3.2.1 Water System User Manual


 
Figure 1-9 HP BladeSystem c3000 Enclosure Bay Locations (Rear View)
1
Interconnect bay #1
2
Fans
3
Interconnect bay #2
4
Enclosure/Onboard Administrator Link Module
5
Power Supplies
6
Interconnect bay #3
7
Interconnect bay #4
1
Enclosure Downlink port
2
Enclosure Uplink port
3
Onboard Administrator/Integrated Lights Out port
Specific HP XC Setup Guidelines
The following enclosure setup guidelines are specific to HP XC:
On every enclosure, an Ethernet interconnect module (either a switch or pass-through
module) is installed in interconnect bay #1 (see callout 1 in Figure 1-9) for the administration
network.
Hardware configurations that use Gigabit Ethernet as the interconnect can share with the
administration network in interconnect bay #1.
Systems that use InfiniBand as the interconnect require a double-wide InfiniBand interconnect
switch module installed in interconnect bays #3 and #4 (see callouts 6 and 7 in Figure 1-9).
Some systems might need an additional Ethernet interconnect module to support server
blades that require external connections. For more information about external connections,
see “Cabling for the External Network” (page 41).
1.2.3 HP BladeSystem c-Class Onboard Administrator
The Onboard Administrator is the management device for an enclosure, and at least one Onboard
Administrator is installed in every enclosure.
1.2 Server Blade Enclosure Components 27