HP (Hewlett-Packard) 3.2.1 Water System User Manual


 
Figure 4-26 HP Integrity rx1620 Server Rear View
PCI-X 133
PCI-X 133
SCSI LVD/SE
LAN 10/100
LAN Gb A
GSP RESETS
SOFTHARD
LAN Gb B
CONSOLE / REMOTE / UPS
SERIAL
USB
The callouts in the figure enumerate the following:
1. The port labeled LAN 10/100 is the MP connection to the ProCurve Console Switch.
2. The port labeled LAN Gb A connects to the Administration Switch (branch or root).
3. The port labeled LAN Gb B is used for an external connection.
Figure 4-27 shows a rear view of the HP Integrity rx2600 server and the appropriate port
assignments for an HP XC system.
The high-speed interconnect card such as an InfiniBand or QsNet
II
card must be inserted into
the top PCI-X slot. The external connection is made on the Ethernet adapter card.
Figure 4-27 HP Integrity rx2600 Server Rear View
VGACONSOLE / REMOTE / UPS
LAN 10/100
LAN Gb
SCSI LVD/SE
USB
CONSOLE
SERIAL A
SERIAL B
PWR
1
PWR
2
Management Card
LAN 10/100
GSP RESETS
SOFTH ARD
TOC
PCI-X 133
PCI-X 133
PCI-X 133
PCI-X 133
The callouts in the figure enumerate the following:
1. The top port labeled LAN 10/100 is the MP connection to the ProCurve Console Switch.
2. The port labeled LAN Gb connects to the Administration Switch (branch or root).
3. The bottom port labeled LAN 10/100 is unused.
Setup Procedure
Perform the following procedure on each HP Integrity server model rx1620 and rx2600:
1. Use the instructions in the accompanying hardware documentation to connect a monitor,
mouse, and keyboard to the node.
2. For each node in the system, ensure that the power cord is connected but that the is not
turned on.
3. Follow this procedure to connect a personal computer to the Management Processor:
a. Connect a three-way DB9-25 cable to the MP DB-25 port on the back of the HP Integrity
rx2600 server.
b. Connect the CONSOLE connector to a null modem cable, and connect the null modem
cable to the PC COM1 port.
c. Use a terminal emulator, such as HyperTerminal, to open a terminal window.
d. Press the Enter key to access the MP. If there is no response, press the MP reset pin on
the back of the MP and try again.
4.9 Preparing the Hardware for CP6000 (Intel Itanium) Systems 123