HP (Hewlett-Packard) 3.2.1 Water System User Manual


 
Table 4-40 iLO Settings for HP ProLiant DL785 G5 Nodes
Set to This ValueOption NameSubmenu NameMenu Name
Create a common iLO user name and password for every
node in the hardware configuration. The password must
have a minimum of 8 characters by default, but this value
is configurable.
The user Administrator is predefined by default, but
you must create your own user name and password. For
security purposes, HP recommends that you delete the
Administrator user.
You must use this user name and password to access the
console port.
AddUser
On
DHCP EnableDNS/DHCPNetwork
115200 (Press the F10 key to save the setting.)Serial CLI
Speed
(bits/seconds)
CLISettings
4. Select FileExit to exit the Integrated Lights Out Setup Utility and resume the power-on
self-test.
5. Watch the screen carefully, and press the F9 key when prompted to access the ROM-Based
Setup Utility (RBSU).
Perform the following procedure for each HP ProLiant DL785 G5 node in the hardware
configuration:
114 Preparing Individual Nodes