Burnham K50 Boiler User Manual


 
4
BOILER SIZE
5006B 5007B 5008B 5009B 5010B 5011B 5012B 5013B 5014B 5015B 5016B 5017B 5018B 5019B 5020B 5021B 5022B 5024B 5026B
(1)
LEH
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
(1)
REH
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
(1)
C
4 5 6 7 8 8 9 10 11 12 13 14 15 16 16 17 18 19 21
(2)
CX
--- --- --- --- --- --- --- --- --- 1 1 1 1 1 1 2 2 3 3
(3)
CXP
--- --- --- --- --- 1 1 1 1 --- --- --- --- --- 1 --- --- --- ---
(1) Section Marking Cast on Section
(2) “C” Cast on Section - When supply and return connections are tapped, section is paint stencilled “CX”
(3) “C” Cast on Section - When supply and return connections are tapped and plugged, section is paint stencilled “CXP”
CARTONS, PACKAGES, OR BUNDLES
1 Base-Burner-Manifold Assembly (By Gas and By Pilot System) - One Left & One Right Req’d on 5015B and Larger Boilers
COMPLETE
1
6
1
7
1
8
1
9
1
10
1
11
1
12
1
13
1
14
--- --- --- --- --- --- --- --- --- ---
L. SUB-BASE --- --- --- --- --- --- --- --- ---
L
1S
15
L
1S
16
L
1S
17
L
1S
18
L
1S
19
L
1S
20
L
1S
21
L
1S
22
L
1S
24
L
1S
26
R. SUB-BASE --- --- --- --- --- --- --- --- ---
R
1S
8
R
1S
9
R
1S
9
R
1S
10
R
1S
10
R
1S
10
R
1S
10
R
1S
10
R
1S
13
R
1S
13
2 Tie Rod Bundle(s) 4 Sizes - One to Five Per Boiler
22” --- --- 1 --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- ---
27” --- --- 1 2 1 --- --- --- 2 1 --- --- --- --- 1 --- --- --- 2
37” 1 --- --- --- 1 2 1 --- 1 2 3 2 1 --- 3 4 3 1 ---
42” --- 1 --- --- --- --- 1 2 --- --- -- 1 2 3 --- --- 1 3 3
2 A Draw-up Rod Bundle(s) 3 Sizes - One to Three Per Boiler
37¾” --- --- --- --- --- 2 2 1 1 --- --- --- --- --- --- --- --- --- ---
49¼” 1 1 --- --- --- --- --- 1 1 2 2 1 1 1 --- --- --- 3 2
67¼” --- --- 1 1 1 --- --- --- --- --- --- 1 1 1 2 2 2 --- 1
3 A Boiler Assembly Carton(s) 6 Sizes - One to Five Per Boiler
3A6 1 --- --- --- --- 1 --- --- --- --- 1 --- --- --- --- 1 --- --- ---
3A7 --- 1 --- --- --- --- 1 --- --- --- --- 1 --- --- --- --- 1 --- ---
3A8 --- --- 1 --- --- --- --- 1 --- --- --- --- 1 --- --- --- --- --- 1
3A9 --- --- --- 1 --- --- --- --- 1 --- --- --- --- 1 --- --- --- 1 1
3A10 --- --- --- --- 1 --- --- --- --- 1 --- --- --- --- 1 --- --- --- ---
3AM --- --- --- --- --- 1 1 1 1 1 2 2 2 2 2 3 3 3 3
4 Boiler Sealing Carton(s) 5 Sizes - One to Three Per Boiler
06 1 --- --- --- --- 2 1 --- --- --- --- --- --- --- 2 --- 1 --- ---
07 --- 1 --- --- --- --- 1 2 1 --- --- --- --- --- --- 2 --- --- ---
08 --- --- 1 --- --- --- --- --- 1 2 1 --- --- --- --- --- --- 1 2
09 --- --- --- 1 --- --- --- --- --- --- 1 2 1 --- --- --- 2 2 1
10 --- --- --- --- 1 --- --- --- --- --- --- --- 1 2 1 1 --- --- ---
5 Integral Drafhood Carton(s) 5 Sizes - One to Four Per Boiler
06 1 --- --- --- --- 2 1 --- --- --- --- --- --- --- 2 1 --- 1 ---
07 --- 1 --- --- --- --- 1 2 1 --- --- --- --- --- --- 1 2 3 3
08 --- --- 1 --- --- --- --- --- 1 2 1 --- --- --- --- --- --- --- ---
09 --- --- --- 1 --- --- --- --- --- --- 1 2 1 --- --- --- --- --- ---
10 --- --- --- --- 1 --- --- --- --- --- --- --- 1 2 1 1 1 --- ---
CANADIAN
EQUIPMENT CHECK LIST
This Equipment Check List has been provided so that the Installer can determine if all parts have been provided for the boiler
ordered. It covers standard equipment for both steam and water boilers without Tankless Heaters. Heaters or optional equipment
ordered will be in addition to, or in lieu of, equipment shown below.
Byopeningcartonsinnumericalsequence,boilerassemblyissimplied.Ifthereisanexception,itwillbepointedoutinthe
boilerassemblyprocedure.Whenitdoesoccur,youwillndthatassemblyoftheboilerisfurthersimplied.