Burnham K50 Boiler User Manual


 
3
BOILER SIZE
5006B 5007B 5008B 5009B 5010B 5011B 5012B 5013B 5014B 5015B 5016B 5017B 5018B 5019B 5020B 5021B 5022B 5024B 5026B
CARTONS, PACKAGES OR BUNDLES
7 S Steam Trim Carton (Steam Boilers Only - Includes PA404 Pressure Limit Control) 4 Sizes - One Per Boiler
1 1 1 1 --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- ---
2 --- --- --- 1 1 1 --- --- --- --- --- --- --- --- --- --- --- --- ---
3 --- --- --- --- --- --- 1 1 1 1 1 1 1 1 1 --- --- --- ---
4 --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- 1 1 1 1
67 BC-2 Low Water Cut-off Carton (Steam Boilers Only) One Per Boiler
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
7 W Water Trim Carton (Water Boilers Only - Includes L4006A Temp. Limit Control) 3 Sizes - One Per Boiler
2 1 1 1 1 1 1 --- --- --- --- --- --- --- --- --- --- --- --- ---
3 --- --- --- --- --- -- 1 1 1 1 1 1 1 1 1 1 1 --- ---
4 --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- 1 1
64 Low Water Cut-off Carton (Water Boilers Only) One Per Boiler
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
U
8
Complete Jacket Carton Assembly - One Per Boiler
9 Gas Train Cartons (By Gas) 2 Sizes - One or Two Per Boiler
9
1
1* 1* 1* --- --- --- --- --- --- 2 1 --- --- --- --- --- --- --- ---
9
2
--- --- --- 1* 1 1 1 1 1 --- 1 2 2 2 2 2 2 2 2
9
3
EI
1 1 1 1 --- --- --- --- --- --- --- --- --- --- --- --- --- --- ---
EI Controls Carton(s) (By Gas) (Intermittent Elec. Ign. - 100% Shutoff - 24V.) 1 Size - One or Two Per Boiler
EI
1
1 1 1 1 --- --- --- --- --- --- --- --- --- --- --- --- --- --- ---
EI
2
--- --- --- --- 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2
U
HCP
1
Plain Heater Cover Plate (Not furnished on Water Boiler Ordered With Two Tankless Heaters) One Per Boiler
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
U
HCP
2
Tapped (¾” NPT) Heater Cover Plate (Not Furnished on Water Boiler Ordered With Tankless Heater(s) One Per Boiler
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
U.S.A. EQUIPMENT CHECK LIST
INSPECT SHIPMENT carefully for any signs of damage. All equipment is carefully manufactured, inspected and packed.
Our responsibility ceases upon delivery of Boiler to carrier in good condition. Any claims for damage or shortage in
shipment
mustbeledimmediatelyagainstthecarrierbytheconsignee.Noclaimsforvariancesorshortageswillbe
allowedbyBoilerManufacturer,unlesspresentedwithinsixty(60)daysafterreceiptofequipment.
*Carton 9
1
, or 9
2
onsizes5006Bthru5009BisstandardonallsystemsexceptEIandmaybeoptionalon5006Bthru
5009BEI.
Carton 9
3
isstandardonsizes5006Bthru5009BforEIsystems.
IMPORTANT INFORMATION
SERVICE ON THIS BOILER SHOULD BE UNDERTAKEN ONLY BY TRAINED AND SKILLED PERSONNEL.
KEEP BOILER AREA CLEAR AND FREE FROM COMBUSTIBLE MATERIALS, GASOLINE AND OTHER
FLAMMABLE VAPORS AND LIQUIDS.
DO NOT PLACE ANY OBSTRUCTION IN THE BOILER ROOM THAT WILL HINDER THE FLOW OF
COMBUSTION AND VENTILATING AIR.
READ
THESE INSTRUCTIONS CAREFULLY BEFORE PROCEEDING WITH THE INSTALLATION OF
BOILER. POST INSTRUCTIONS NEAR BOILER FOR REFERENCE BY OWNER AND SERVICEMAN.
MAINTAIN INSTRUCTIONS IN LEGIBLE CONDITION.