Trane RTAC 140-400 ton units (50 HZ) Air Conditioner User Manual


 
RTAC-SVX01F-EN 27
Digit 1-4
Unit Model
RTAC Air Cooled Series R® chiller
Digit 5-7
Unit Nominal Capacity
140 140 Nominal Tons
155 155 Nominal Tons
170 170 Nominal Tons
185185 Nominal Tons
200 200 Nominal Tons
225 225 Nominal Tons
250 250 Nominal Tons
275 275 Nominal Tons
300 300 Nominal Tons
350 350 Nominal Tons
375 375 Nominal Tons
400 400 Nominal Tons
450 450 Nominal Tons
500 500 Nominal Tons
Digit 8
Unit Voltage
A 200V/60Hz/3Ph power
K 220V/50Hz/3 Ph power
C 230V/60Hz/3Ph power
J380V/60Hz/3Ph power
D 400V/50Hz/3Ph power
4 460V/60Hz/3Ph power
5 575V/60Hz/3Ph power
Digit 9
Manufacturing Location
U Pueblo
ECharmes
Digit 10-11
Design Sequence
XX Factory/ABU Assigned
Digit 12
Unit Type
N Std. Efficiency/Performance
H High Efficiency/Performance
Digit 13
Agency Listing
N No agency listing
U C/UL listing
Digit 14
Pressure Vessel Code
A ASME pressure vessel code
C Canadian code
D Australian code
L Chinese code
R Vietanamese code
S Special
Digit 15
Evaporator Temperature Range &
Application Type
F Standard Temp. with Frz Prot
RRem Evap, Std. Temp, No Frz
Prot
G Low Temp, with Frz Prot
Digit 16
Evaporator Configuration
N Standard pass arrangement,
insulated
Digit 17
Condenser Temperature Range
N Standard ambient range
25-115 deg F
H High ambient capability
25-125 deg F
LLow ambient capability
0-115 deg F
WWide ambient capability
0-125 deg F
Digit 18
Condenser Fin Material
1 Standard aluminum slit fins
2 Copper fins, non-slit fins
4Complete Coat aluminum fins
Digit 19
Condenser Fan/Motor Configuration
N Condenser fans with ODP
motors
W Low Noise fans
T Condenser fans with TEAO
motors
Digit 20
Compressor Motor Starter Type
X Across-the-line starters
Y Wye-delta closed transition
starters
Digit 21
Incoming Power Line Connection
1 Single point power connection
2 Dual point power connection (1/
ckt)
Digit 22
Power Line Connection Type
TTerminals only
D Non-fused disconnect
switch(es)
C Circuit Breaker(s), HACR-rated
Digit 23
Unit Operator Interface
E Easy-View operator interface
D Dyna-View operator interface
Digit 24
Remote Interface
N No remote interface
C Tracer Comm 3 interface
LLon Talk Communication interface
(LCI)
Digit 25
Control Input Accessories/Options
N No remote input
RRemote leaving water temp stpt
CRemote current limit setpoint
BRemote lvg. temp.setpoint and
remote current limit setpoint
Digit 26
COOP 26
Control Output Accessories/Options
N No output options
AAlarm relay
CIcemaking
DIcemaking and alarm relay
Digit 27
Short Circuit Rating
0 No short circuit withstand rating
5 10000A SCR
4 35000A SCR
6 65000A SCR
Digit 28
Electrical Accessories and Export
Packing
N No flow switches
F NEMA-1 flow switch - 150 psi
E Vapor Proof FS - 150 psi
Digit 29
Control Panel Accessories
N No convenience outlet
A 15A 115V convenience outlet
(60HZ)
Digit 30
Refrigerant Service Valves
1 Suction service valves
Digit 31
Compressor Sound Attenuator
Option
0 No sound attenuator
1 Factory installed sound attenuator
Digit 32
Appearance Options
N No appearance options
A Architectural louvered panels
CHalf Louvers
G Access guards
B Access guards and half louvers
P Painted unit
L Painted unit with full louvered
panels
H Painted unit with half louvered
panels
K Painted unit with access guards
W Painted w/access guards and half
louvers
Digit33
Installation Accessories
N No installation accessories
R Neoprene isolators
F Flanged water connection kit
G Neoprene isolators and flange
wtr conn kit
Digit 34
Factory Test
0 No factory run test
P Performance test
WWitness test
Digit 35
Label, and Literature Language
EEnglish
G Chinese
Digit 36
Special Order
X Standard catalog configuration
S Unit has special order feature
Digit 37
Safety Devices
N None
X Standard