Trane RTAC 140-400 ton units (50 HZ) Air Conditioner User Manual


 
128 RTAC-SVX01F-EN
Diagnostics
698 Comm Loss: Fan Inverter
Power, Circuit #2 or Circuit #2
Drive 1 and 2
Normal Latch Same as Comm Loss: Fan Inverter Fault, Circuit #1 or Circuit #1,
Drive 1
Remote
68B Comm Loss: Fan Inverter
Speed Command, Circuit #1
or Circuit #1 Drive 1 and 2
Special
Mode
Latch Same as Comm Loss: Fan Inverter Fault, Circuit #1 or Circuit #1,
Drive 1
Remote
699 Comm Loss: Fan Inverter
Speed Command, Circuit #2
or Circuit #2 Drive 1 and 2
Special
Mode
Latch Same as Comm Loss: Fan Inverter Fault, Circuit #1 or Circuit #1,
Drive 1
Remote
5D9 Comm Loss: Female Step
Load Compressor 1A
Normal Latch Same as Comm Loss: Chilled Water Flow Switch Remote
5DA Comm Loss: Female Step
Load Compressor 1B
Normal Latch Same as Comm Loss: Chilled Water Flow Switch Remote
5DB Comm Loss: Female Step
Load Compressor 2A
Normal Latch Same as Comm Loss: Chilled Water Flow Switch Remote
5DC Comm Loss: Female Step
Load Compressor 2B
Normal Latch Same as Comm Loss: Chilled Water Flow Switch Remote
5EB Comm Loss: High Pressure
Cutout Switch, Cprsr 1A
Immediate Latch Same as Comm Loss: Chilled Water Flow Switch Remote
5EC Comm Loss: High Pressure
Cutout Switch, Cprsr 1B
Immediate Latch Same as Comm Loss: Chilled Water Flow Switch Remote
5ED Comm Loss: High Pressure
Cutout Switch, Cprsr 2A
Immediate Latch Same as Comm Loss: Chilled Water Flow Switch Remote
5EE Comm Loss: High Pressure
Cutout Switch, Cprsr 2B
Immediate Latch Same as Comm Loss: Chilled Water Flow Switch Remote
5E1 Comm Loss: Ice-Machine
Control
Special
Mode
Latch Continual loss of communication between the MP and the Functional
ID has occurred for a 30 second period. Chiller shall revert to normal
(non-ice building) mode regardless of last state.
Remote
5FA Comm Loss: Ice-Making
Status
Special
Mode
Latch Same as Comm Loss: Ice-Machine Control Remote
5F4 Comm Loss: Intermediate Oil
Pressure, Cprsr 1A
Immediate Latch Same as Comm Loss: Chilled Water Flow Switch Remote
5F5 Comm Loss: Intermediate Oil
Pressure, Cprsr 1B
Immediate Latch Same as Comm Loss: Chilled Water Flow Switch Remote
5F6 Comm Loss: Intermediate Oil
Pressure, Cprsr 2A
Immediate Latch Same as Comm Loss: Chilled Water Flow Switch Remote
5F7 Comm Loss: Intermediate Oil
Pressure, Cprsr 2B
Immediate Latch Same as Comm Loss: Chilled Water Flow Switch Remote
69D Comm Loss: Local BAS
Interface
Special
Mode
Latch Same as Comm Loss: Chilled Water Flow Switch Remote
5D2 Comm Loss: Male Port Load
Compressor 1A
Normal Latch Same as Comm Loss: Chilled Water Flow Switch Remote
5D4 Comm Loss: Male Port Load
Compressor 1B
Normal Latch Same as Comm Loss: Chilled Water Flow Switch Remote
5D6 Comm Loss: Male Port Load
Compressor 2A
Normal Latch Same as Comm Loss: Chilled Water Flow Switch Remote
5D8 Comm Loss: Male Port Load
Compressor 2B
Normal Latch Same as Comm Loss: Chilled Water Flow Switch Remote
5D1 Comm Loss: Male Port
Unload Compressor 1A
Normal Latch Same as Comm Loss: Chilled Water Flow Switch Remote
5D3 Comm Loss: Male Port
Unload Compressor 1B
Normal Latch Same as Comm Loss: Chilled Water Flow Switch Remote
5D5 Comm Loss: Male Port
Unload Compressor 2A
Normal Latch Same as Comm Loss: Chilled Water Flow Switch Remote
5D7 Comm Loss: Male Port
Unload Compressor 2B
Normal Latch Same as Comm Loss: Chilled Water Flow Switch Remote
5E5 Comm Loss: Oil
Temperature, Circuit #1 or
Cprsr 1A
Normal Latch Same as Comm Loss: Chilled Water Flow Switch Remote
5E6 Comm Loss: Oil
Temperature, Circuit #2 or
Cprsr 2A
Normal Latch Same as Comm Loss: Chilled Water Flow Switch Remote
696 Comm Loss: Oil
Temperature, Cprsr 1B
Normal Latch Same as Comm Loss: Chilled Water Flow Switch Remote
697 Comm Loss: Oil
Temperature, Cprsr 2B
Normal Latch Same as Comm Loss: Chilled Water Flow Switch Remote
Hex
Code
Diagnostic Name
and Source
Severity Persis-
tence
Criteria Reset
Level