Motion Control Modules Section 2-4
Pulse I/O Specifications FQM1-MMP21 (Pulse I/O)
Item Specifications
Pulse
inputs
Number of counters 2
Counter operations Linear counter and circular counter
Input signals Two words each for phase A, phase B, and phase Z.
Signal levels 24 V DC, line-driver
Input method Phase differential ×1
Phase differential ×2
Phase differential ×4
Increment/decrement
Pulse + direction
Counting speed Voltage 50 k Hz
Line-driver 50 k Hz/500k Hz (phase differen-
tial × 4, 2 MHz)
Absolute Servo
Driver interfaces
2
SEN output specifications: 5 V PNP output, output
current: 5 mA
When SEN signal is output to Servo Driver, Servo
Driver will transmit the number of encoder's rotations
to this Module. After that, it transmits pulse train cor-
responding to displacement of the number of turns to
the Module.
Pulse
outputs
Number of outputs 2
Output signal CW/CCW
Signal levels Line-driver (equivalent to AM26LS31)
Max. output current: 20 mA
Output speed 1 MHz
One-
shot
pulse
outputs
Number of outputs 2
Output type Open collector (NPN)
Max. switching
capacity
80 mA/5 to 24 V DC ± 10%
Min. switching
capacity
7 mA/5 to 24 VDC ± 10%
Output pulse width Set time ± 1 µs or 0.1% of set time