244
Error Processing Section 9-2
9-2-3 Error Codes
ERRONOFFOFFONFlashing--- --- ---
PRPHL --- --- --- --- --- OFF --- ---
COMM1 --- --- --- --- --- --- OFF ---
COMM2 --- --- --- --- --- --- --- OFF
Classification Error code Error name Page
Fatal system
errors
80F1 Memory error 244
80C0 I/O bus error 244
80CE No End Cover 244
80CF Synchronous bus error 244
80E0 I/O setting error 244
80F0 Program error 244
809F Cycle time overrun error 244
Non-fatal sys-
tem errors
009B System Setup setting error 244
0001 Coordinator Module WDT error 244
0006 Coordinator Module error 244
0300 Motion Control Module WDT error 244
User-defined
non-fatal errors
4101 to 42FF FAL error
(4101 to 42FF are stored for FAL num-
bers 001 to 511)
244
User-defined
fatal errors
C101 to C2FF FALS error
(C101 to C2FF are stored for FALS
numbers 001 to 511)
244
Indicator CPU error CPU reset CPU
standby
Fatal error Non-fatal
error
Communications error
Peripheral RS-232C RS-422A