345
System Setup, Auxiliary Area Allocations, and Built-in I/O Allocations Appendix C
FAL/FALS Errors
Memory Errors
System Setup
I/O Errors
Module Errors
A500 14 Error Log Pointer Reset
and Memory Not Held
Flag OFF Bit
The error log pointer in A408 is reset to 0000 hex and Memory Not
Held Flag (A404.14) is turned OFF when this bit is turned ON.
User
A400 00 to 15 Error code When a non-fatal error (user-defined FAL(006) or system error) or a
fatal error (user-defined FALS(007) or system error) occurs, the hexa-
decimal error code is written to this word.
Module
Address Bits Name Function Controlled by
A401 06 FALS Error Flag
(fatal error)
Turns ON when a non-fatal error is generated by the FALS(006)
instruction. The FQM1 will stop operating.
Module
A402 15 FAL Error Flag
(non-fatal error)
Turns ON when a non-fatal error is generated by executing FAL(006).
The FQM1 will continue operating.
Address Bits Name Function Controlled by
A401 15 Memory Error Flag (fatal
error)
Turns ON when there is an error in the memory. FQM1 operation will
stop and the ERR indicators on the front of the Modules will light.
Module
A403 00 UM Error Flag Turns ON when there is an error in the user memory.
04 System Setup Error
Flag
Turns ON when there is an error in the System Setup in the Coordina-
tor Module or Motion Control Module.
10 Flash Memory Error
Flag
Turns ON when the flash memory is physically destroyed.
13 Analog Offset/Gain
Error Flag
Turns ON when there is an error in the analog I/O offset/gain adjust-
ment value in flash memory.
14 Flash Memory DM
Checksum Error Flag
Turns ON when there is an error in the DM Area data backed up in
flash memory in the Coordinator Module.
A404 14 Memory Not Held Flag Turns ON when corruption is found in the check performed after turn-
ing ON power in the areas backed up during power interruptions (DM
Area (Coordinator Module only) and Error Log Area).
Address Bits Name Function Controlled by
A402 10 System Setup Error
Flag
Turns ON when there is a setting error in the System Setup. Module
A409 00 to 15 System Setup Error
Location
When there is a setting error in the System Setup, the location of that
error is written to A409 in 4-digit hexadecimal.
Address Bits Name Function Controlled by
A401 10 I/O Setting Error Flag Turns ON when more than four Motion Control Modules are connected
to the Coordinator Module.
Module
Address Bits Name Function Controlled by
A402 05 Motion Control Module
Monitoring Error Flag
(Coordinator Module
only)
Turns ON in the Coordinator Module when a system error, such as a
WDT error, occurs in any of the Motion Control Modules.
Module
13 Coordinator Module
WDT Error Flag (Motion
Control Modules only)
Turns ON in the Motion Control Modules when a WDT error occurs in
the Coordinator Module.
14 Coordinator Module
Fatal Error Flag (Motion
Control Modules only)
Turns ON in the Motion Control Modules when a fatal error occurs in
the Coordinator Module.
Address Bits Name Function Controlled by