(3) Transportation and installation
CAUTION
Transport the product with the correct method according to the weight.
Use the servomotor suspension bolts only for the transportation of the servomotor. Do not
transport the servomotor with machine installed on it.
Do not stack products past the limit.
When transporting the control unit or servo amplifier, never hold the connected wires or
cables.
When transporting the servomotor, never hold the cables, shaft or detector.
When transporting the control unit or servo amplifier, never hold the front case as it may fall
off.
When transporting, installing or removing the control unit or servo amplifier, never hold the
edges.
Install the unit according to the instruction manual in a place where the weight can be withstood.
Do not get on or place heavy objects on the product.
Always observe the installation direction.
Keep the designated clearance between the control unit or servo amplifier and control panel
inner surface or the control unit and servo amplifier, control unit or servo amplifier and other
devices.
Do not install or operate control units, servo amplifiers or servomotors that are damaged or
that have missing parts.
Do not block the intake/outtake ports of the servomotor with cooling fan.
Do not allow conductive matter such as screw or cutting chips or combustible matter such
as oil enter the control unit, servo amplifier or servomotor.
The control unit, servo amplifier and servomotor are precision machines, so do not drop or
apply strong impacts on them.
Securely fix the control unit and servo amplifier to the machine according to the instruction
manual. If the fixing is insufficient, these may come off during operation.
Always install the servomotor with reduction gears in the designated direction. Failing to do
so may lead to oil leaks.
Store and use the unit in the following environmental conditions.
Conditions
Environment
Control unit/servo amplifier Servomotor
Ambient
temperature
0
°
C to
+
55
°
C
(With no freezing)
0
°
C to
+
40
°
C
(With no freezing)
Ambient humidity
According to each instruction
manual.
80
%
RH or less
(With no dew condensation)
Storage
temperature
According to each instruction
manual.
20
°
C to
+
65
°
C
Atmosphere
Indoors (where not subject to direct sunlight).
No corrosive gases, flammable gases, oil mist or dust must exist
Altitude 1000m (3278.69ft.) or less above sea level
Vibration According to each instruction manual