Johnson Controls R-410A Heat Pump User Manual


 
505429-JTG-F-1010
Johnson Controls Unitary Products 37
115°F 125°F
4500
77 175.1 17.7 89.8 71.1 52.5 - - - 161.0 19.4 84.1 65.6 47.1 - - -
72 163.9 17.4 117.8 99.2 80.6 61.9 - - 152.2 19.1 113.1 94.6 76.1 57.6 - -
67 152.8 17.2 145.9 127.3 108.6 90.0 71.4 - 143.4 18.9 142.1 123.6 105.1 86.6 68.0 -
62 144.6 17.1 144.6 144.6 134.7 116.0 97.4 78.8 135.8 18.8 135.8 135.8 128.1 109.5 91.0 72.5
57 146.8 17.0 146.8 146.8 141.1 122.5 103.9 85.2 136.8 18.7 136.8 136.8 136.6 118.0 99.5 81.0
5250
77 181.4 17.7 106.1 78.6 57.4 - - - 167.8 19.4 103.6 73.2 52.2 - - -
72 169.9 17.5 130.5 109.3 88.1 66.9 - - 158.6 19.2 126.2 105.2 84.1 63.1 - -
67 158.3 17.2 154.9 140.0 118.8 97.6 76.4 - 149.4 18.9 148.7 137.1 116.1 95.1 74.0 -
62 149.8 17.1 149.8 149.8 147.3 126.1 104.9 83.7 141.5 18.9 141.5 141.5 141.5 120.9 99.5 78.5
57 152.1 17.0 152.1 152.1 154.3 133.1 112.0 90.8 142.5 18.7 142.5 142.5 142.5 130.2 108.8 87.8
6000
77 187.8 17.8 122.4 86.1 62.3 - - - 174.5 19.4 123.1 80.8 57.2 - - -
72 175.8 17.5 143.1 119.4 95.6 71.9 - - 164.9 19.2 139.2 115.7 92.2 68.6 - -
67 163.9 17.3 163.9 152.7 129.0 105.2 81.5 - 155.3 19.0 155.3 150.7 127.1 103.6 80.0 -
62 155.1 17.2 155.1 155.1 159.9 136.1 112.4 88.7 147.1 18.9 147.1 147.1 147.1 132.2 108.0 84.4
57 157.5 17.1 157.5 157.5 167.5 143.8 120.1 96.3 148.2 18.8 148.2 148.2 148.2 142.4 118.1 94.6
6750
72 174.6 17.6 153.0 127.0 101.1 75.1 - - 162.6 19.2 149.2 123.1 97.0 71.0 - -
67 162.8 17.3 162.8 157.2 136.3 110.3 84.3 - 153.2 19.0 153.2 152.4 133.9 107.8 81.8 -
62 154.0 17.2 154.0 154.0 156.4 130.5 104.5 78.5 145.1 19.0 145.1 145.1 145.1 123.3 96.9 70.9
57 156.4 17.1 156.4 156.4 161.4 135.5 109.5 83.5 146.1 18.8 146.1 146.1 146.1 128.9 102.5 76.4
7500
72 173.5 17.6 162.9 134.7 106.5 78.3 - - 160.3 19.3 159.1 130.5 101.9 73.3 - -
67 161.7 17.3 161.7 161.7 143.6 115.4 87.2 - 151.0 19.0 151.0 151.0 140.6 112.0 83.5 -
62 153.0 17.2 153.0 153.0 153.0 124.8 96.6 68.4 143.0 19.0 143.0 143.0 143.0 114.5 85.9 57.3
57 155.4 17.1 155.4 155.4 155.4 127.2 99.0 70.8 144.0 18.8 144.0 144.0 144.0 115.5 86.9 58.3
1
These capacities are gross ratings. For net capacity, deduct supply air blower motor, MBh. Example: Refer to the appropriate Blower
Performance Table for the BHP of the supply air blower motor, MBh = 3.415 x kW and kW = BHP x 0.746
nameplate rated motor
efficiency.
2. These ratings include the condenser fan motors and the compressor motors but not the supply air blower motor.
J15YD/J15ND (Continued)
Air on
Evaporator Coil
Temperature of Air on Condenser Coil
Total
Capacity
1
(MBh)
Total
Input
(kW)
2
Sensible Capacity (MBh)
Total
Capacity
1
(MBh)
Total
Input
(kW)
2
Sensible Capacity (MBh)
CFM
WB
(°F)
Return Dry Bulb (°F) Return Dry Bulb (°F)
90 85 80 75 70 65 90 85 80 75 70 65