Cisco Systems 15454-FTF2 Home Security System User Manual


 
C-55
Cisco ONS 15454 Reference Manual, R8.5.x
78-18106-01
Appendix C Network Element Defaults
C.2.3 Defaults by Card
OC192.config.line.sonet.AdminSSMIn STU PRS, STU, ST2, ST3, SMC, ST4,
DUS, RES when
//.//.//.//.NODE.timing.general.SSM
MessageSet Generation 1; PRS,
STU, ST2, TNC, ST3E, ST3, SMC,
ST4, DUS, RES when
//.//.//.//.NODE.timing.general.SSM
MessageSet Generation 2; PRS,
STU, ST2, ST3, SMC, ST4, DUS,
RES when
//.//.//.//.NODE.timing.general.SSM
MessageSet N/A
OC192.config.line.sonet.Send<FF>DoNotUse FALSE FALSE when SendDoNotUse TRUE;
FALSE, TRUE when SendDoNotUse
FALSE
OC192.config.line.sonet.SendDoNotUse FALSE FALSE, TRUE
OC192.config.line.sonet.SyncMsgIn TRUE FALSE, TRUE
OC192.config.line.State IS,AINS IS, OOS,DSBLD, OOS,MT, IS,AINS
OC192.config.sts.IPPMEnabled FALSE TRUE, FALSE
OC192.physicalthresholds.alarm.LBC-HIGH 200 (%) LBC-LOW, LBC-LOW + 1,
LBC-LOW + 2 .. 255
OC192.physicalthresholds.alarm.LBC-LOW 20 (%) 0, 1, 2 .. LBC-HIGH
OC192.physicalthresholds.alarm.OPR-HIGH 200 (%) OPR-LOW, OPR-LOW + 1,
OPR-LOW + 2 .. 255
OC192.physicalthresholds.alarm.OPR-LOW 50 (%) -1, 0, 1 .. OPR-HIGH
OC192.physicalthresholds.alarm.OPT-HIGH 120 (%) OPT-LOW, OPT-LOW + 1,
OPT-LOW + 2 .. 255
OC192.physicalthresholds.alarm.OPT-LOW 80 (%) 0, 1, 2 .. OPT-HIGH
OC192.physicalthresholds.warning.15min.LBC-HIGH 200 (%) LBC-LOW, LBC-LOW + 1,
LBC-LOW + 2 .. 255
OC192.physicalthresholds.warning.15min.LBC-LOW 20 (%) 0, 1, 2 .. LBC-HIGH
OC192.physicalthresholds.warning.15min.OPR-HIGH 200 (%) OPR-LOW, OPR-LOW + 1,
OPR-LOW + 2 .. 255
OC192.physicalthresholds.warning.15min.OPR-LOW 50 (%) -1, 0, 1 .. OPR-HIGH
OC192.physicalthresholds.warning.15min.OPT-HIGH 120 (%) OPT-LOW, OPT-LOW + 1,
OPT-LOW + 2 .. 255
OC192.physicalthresholds.warning.15min.OPT-LOW 80 (%) 0, 1, 2 .. OPT-HIGH
OC192.physicalthresholds.warning.1day.LBC-HIGH 200 (%) LBC-LOW, LBC-LOW + 1,
LBC-LOW + 2 .. 255
OC192.physicalthresholds.warning.1day.LBC-LOW 20 (%) 0, 1, 2 .. LBC-HIGH
OC192.physicalthresholds.warning.1day.OPR-HIGH 200 (%) OPR-LOW, OPR-LOW + 1,
OPR-LOW + 2 .. 255
Table C-17 OC-192 Card Default Settings (continued)
Default Name Default Value Default Domain