7-6
Cisco ONS 15454 Reference Manual, R8.5.x
78-18106-01
Chapter 7 Card Protection
7.2 Electrical Card Protection and the Backplane
Table 7-4 shows the electrical card protection for each EIA type according to shelf side and slots.
Maximum HD DS-1 interfaces (Tx and Rx) — — — — — 112
Maximum HD DS-3 interfaces (Tx and Rx) — — 96 — — 96
Table 7-3 EIA Connectors Per Side
Interfaces per Side
Standard
BNC
High-Density
BNC MiniBNC SMB AMP Champ
UBIC-V and
UBIC-H (SCSI)
Table 7-4 Electrical Card Protection By EIA Type
Protection
Type Card Type Side Standard BNC High-Density BNC MiniBNC SMB
AMP
Champ
UBIC-V and
UBIC-H (SCSI)
Unprotected LD, Working A 2, 4 1, 2, 4, 5 1–6 1–6 1–6 1–6
B 14, 16 13, 14, 16, 17 12–17 12–17 12–17 12–17
HD, Working A — — 1, 2 — — 1, 2
B — — 16, 17 — — 16, 17
1:1 LD, Working A 2, 4 2, 4 2, 4, 6 2, 4, 6 2, 4, 6 2, 4, 6
B 14, 16 14, 16 12, 14, 16 12, 14, 16 12, 14, 16 12, 14, 16
LD, Protect A 1, 3 1, 3 1, 3, 5 1, 3, 5 1, 3, 5 1, 3, 5
B 15, 17 15, 17 13, 15, 17 13, 15, 17 13, 15, 17 13, 15, 17
1:N LD, Working A — 1, 2, 4, 5 1–6 1–6 1–6 1–6
B — 13, 14, 16, 17 12–17 12–17 12–17 12–17
LD, Protect A — 3 3 3 3 3
B — 15 15 15 15 15
HD, Working A — — 1, 2 — — 1, 2
B — — 16, 17 — — 16, 17
HD, Protect A — — 3 — — 3
B— — 15 — — 15