Wolverine Siding and Vinyl Carpentry Soffit and Decorative Trim Siding User Manual


 
Random Hand-Split Shakes
Overview
The installation of Random Hand-Split Shake is unique in that
the lap joint is hidden in the ribs between the shake patterns.
Positioning the laps in the rib area requires that special
installation procedures be followed to maintain product
performance and aesthetics.
Factory Laps: All lap joints are cut at a predetermined point on
the panel during the manufacturing process. All laps must be
factory cut. There should be NO field cutting of laps.
Install from right to left: Panels must be installed from right to
left. The left panel will overlap the right panel.
Center Pinning: Each panel contains a short vertical slot,
perpendicular to the nail slots which indicates the center of the
panel. To maintain an aesthetically correct rib width at the lap
joint for warm and cold temperatures, it is necessary to limit
panel movement. This is accomplished by center pinning all
panels. Center pinning will prevent the rib width at the lap joint
from becoming too wide or too narrow.
Install the siding according to one of the following methods,
depending on whether the substrate is or is not fully nailable.
Installation procedure for fully nailable substrate
Lock the right side panel into place on the starter strip. Allow
room for expansion and contraction in all accessory pockets:
• 1/4" if temperature is above 40° F.
• 3/8" if temperature is below 40° F.
Locate the short, vertical slot on the nail hem and center pin
the panel in this location using one of the following options:
a. Install a nail on both ends of the same nail slot.
b. Pin the panel by fastening directly through the nail hem.
c. Drill a 3/16" diameter hole through the nail hem and
substrate, and place a single fastener through this newly
drilled hole.
Install nails in the center of the remaining slots, 16" apart.
Leave adequate room between the fastener head and the nail
flange for expansion and contraction (approximately 1/16" to
1/8").
IMPORTANT: DO NOT HARD NAIL THESE FASTENERS.
100
Wolverine Fit and Finish Installation Guide