RETRACTING THE CARTRIDGE
1. Insert the manual release tool onto the D-shaped shaft at
the front of the drive as shown below to operate the
cartridge insertion mechanism. Turn the tool clockwise as
far as it will turn, pulling the cartridge back into the shuttle.
Figure 51. LF 8600 Manual Cartridge Retraction
2. Manually move the shuttle to the home position as shown
below.
3. Remove the cartridge from the shuttle slot.
Figure 52. Manually Moving the Shuttle Assembly to the Home
Position
FRONT
ACCESS