PLASMON L M S - LF 8600 USER MANUAL
Page 76
A structure diagram for the Diagnostics menu is shown in the next figure.
To move up a level in the configuration menu hierarchy to the Main menu, press the LOAD/MENU and
TEST/SELECT switches simultaneously.
To exit the Configuration mode, press the LOAD/MENU and TEST/SELECT switches simultaneously from
the Main menu. The display will show the message which appeared prior to the drive entering the
Configuration mode.
"Clear RTPM" CAUTION
RTPM errors indicate the drive or media require maintenance, and place the
drive in a read only mode. Corrective action may be as simple as cleaning the
media that caused the error, or may require the attention of a trained
Customer Engineer (CE) to repair the drive. Clearing this error without
resolving the cause may reduce the total media capacity because of
abnormally high relocations during write operations.
Press the SELECT switch; if an RTPM error has not occurred, the message
"No RTPM Err" will briefly appear and the display will return to "Clear RTPM".
If an RTPM has occurred, a confirmation message will be displayed. Press
the SELECT switch to clear the RTPM error and enable writing. Press the
MENU switch to select the next option in the Diagnostic (Park Drive) menu
without clearing the RTPM error. The drive will not perform write operations
with an RTPM error.
"Init DPC" Press SELECT switch to Initialize DPC. This option will clear all the serial
E-Prom values and reset the drive.
"WPC Options" Press the SELECT switch. "Force WPC" is displayed. If Write Calibration is
required, press the SELECT switch again. The Drive will cycle through the
WPC Write, WPC GOOD, and back to Force WPC messages.
Press the MENU switch to display Clear WPC. If the WPC log needs to be
cleared from the Drive, press SELECT again. When the WPC Log has been
cleared, the message WPC CLEARED will be momentarily displayed. When
Clear WPC is displayed, press MENU and MENU/SELECT simultaneously to
return to the Diagnostic Menu.